Troubleshooting(continued)
Burner(s)will not light
usingignitor.
(SeeElectronicIgnition
Troubleshootingalso)
Burner(s)will not
matchlight.
Suddendropin gas
floworlow flame.
Flamesblowout.
Flare-up.
ELECTRONICIGNITION:
• Nospark,noignitionnoise.
• Nospark,someignitionnoise.
• Sparks,but notat electrodeorat full
strength.
• See"GAS ISSUES:"onpreviouspage.
• Matchwill not reach.
• Impropermethodof match-lighting.
Unableto fill LP
cylinder.
Oneburnerdoes not
lightfromother
burner(s).
Timerdoesnot work
(Greenlightdoesnot
flash)
• Outof gas.
• Excessflowvalvetripped.
•Vaporlockatcouplingnut/LPcylinder
connection.
• Highorgustingwinds.
• LowonLPgas.
• Excessflowvalvetripped.
• Greasebuildup.
• Excessivefat in meat.
• Excessivecookingtemperature.
• Greasetrappedby foodbuilduparound
burnersystem.
• SeeSectionI ofElectronicIgnitionSystem.
• SeeSectionII ofElectronicIgnitionSystem.
• SeeSectionIIIof ElectronicIgnitionSystem.
• Uselong-stemmatch(fireplacematch).
• See"Match-Lighting"sectionof UseandCare.
• Checkfor gasin LPcylinder.
•Turnoff knobs,wait30secondsandlightgrill. Ifflamesarestilllow,
turnoff knobsandLPcylindervalve.Disconnectregulator.
Reconnectregulatorandleak-test.Turnon LPcylindervalve,wait
30secondsandthenlightgrill.
•Turnoff knobsandLPcylindervalve.Disconnectcouplingnutfrom
cylinder.Reconnectandretry.
•Turnfrontof grillto facewindor increaseflameheight.
• RefillLPcylinder.
• Referto"Suddendropin gasflow"above.
• Cleanburnersand insideof grill/firebox.
•Trimfatfrommeatbeforegrilling.
•Adjust(lower)temperatureaccordingly.
•Turnknobsto OFF.Turngas offat LPcylinder.Leavelidin position
andlet fire burnout.Aftergrillcools,removeandcleanall parts.
Persistentgreasefire.
Flashback... • Burnerand/orburnertubesare blocked. •Turnknobsto OFF.Cleanburnerand/orburnertubes.Seeburner
(firein burnertube(s)), cleaningsectionof UseandCare.
• Somedealershaveolderfill nozzles •Thewornnozzlesdon'thaveenough"bite"to engagethe valve.Try
withworn threads, a secondLPdealer.
• Cleancarry-overtube(s)withwirebrush.
• Greasebuildupor foodparticlesin
end(s)of carryovertube(s).
, DeadBattery
, Batteriesinstalledincorrectly.
, KnobPositiondid notstart the Clean
Cycle
, Replacebatteries
, Installbatteriescorrectly.
, PushKnobin to startthe cleancycle.(GreenLEDshouldbeginto
flash)
No LED'swill illuminate , DeadBattery , Replacebatteries
, LowBatteryStrengthRedLED nextto battery
symbolis illuminated
, Prepareto replacebatteries(NOTE:Cleancyclewill operatewith
a weakbattery.
29
Comments to this Manuals